##  [Label Artwork Proofreading &amp; Quality Control](/medical-devices/label-artwork-proofreading-quality-control) 

# Label Artwork Proofreading &amp; Quality Control

Artwork proofreading services and structured QC for medical device labels, including comparative text verification, symbol accuracy checks, barcode grade assessment, regulatory compliance review, and signed audit-trail documentation.



- 2
    
    
    
    QC review layers per artwork
- 100%
    
    
    
    Documented audit trail per file
- Zero
    
    
    
    Text discrepancies
- All
    
    
    
    Device classes &amp; label types supported
- NB &amp; FDA
    
    
    
    Inspection-ready records







### Speak to our Experts











## What is Label Artwork Proofreading &amp; Quality Control?

Medical device artwork proofreading and quality control (QC) is a structured verification process confirming the accuracy, completeness, legibility, and regulatory compliance of labels before receiving approval for printing, distribution, or commercial release. This process involves an independent review of finished or draft artwork against approved source content, regulatory requirements, product specifications, and applicable quality standards.

Regulatory authorities worldwide require manufacturers to implement documented controls to ensure labeling accuracy. FDA label compliance under 21 CFR 820.120 and 21 CFR Part 801 mandates inspection of labeling for accuracy, including critical data such as device identification, control numbers, lot information, and expiration dates before use. Meeting EU MDR labeling requirements and achieving compliance requires manufacturers to maintain controlled procedures for the review, approval, and release of labeling as part of an effective QMS.



![]()



Freyr's Medical device label artwork quality control services provide an independent, multi-level artwork verification framework combining advanced automated inspection technologies, including GlobalVision and TVT, with experienced quality specialists. Every component of medical device artwork validation - text, graphics, symbols, barcodes, variable data, dimensions, and regulatory statements is systematically reviewed under this framework, documented in a complete, audit-ready quality record that supports FDA Device History Record (DHR) requirements, ISO 13485 compliance, and Notified Body technical documentation expectations.



##### Independent Review - A Regulatory Requirement, Not Optional

ISO 13485:2016 §7.5.1 and 21 CFR 820.120 both require that labeling be reviewed and approved by individuals other than those who performed the work. Self-review is not acceptable; the author is cognitively predisposed to miss their own errors. Freyr, as a third-party QC provider, inherently satisfies this requirement.













## Freyr's Label QC Framework

Every Freyr label artwork QC engagement has distinct, documented review layers, each targeting different error types and using different verification methods.



 

#### Comparative Text Verification

Label content verification services include character-by-character comparison of every text string in the artwork against the approved source label text document, functioning as a thorough label inspection service. Zero tolerance for transposition, missing words, punctuation differences, or spacing variations. Applied using both automated tools and trained human reviewers.

- Every text field compared against the approved copy source document, including all regulatory statements, device names, addresses, dates, and codes
- All language versions compared against their respective approved translations
- Automated comparison via electronic proofreading tool "Text Inspection" which flags all text deviations, including character substitutions, missing words, and spacing differences
- Manual side-by-side verification of warning statements, symbols with text, and date fields
- Discrepancy report produced - every finding documented with exact location and discrepancy type



 

#### Regulatory Compliance Review

Regulatory artwork review of every mandatory element against the applicable regulatory framework. A trained regulatory specialist, not a general proofreader, uses a structured label QC checklist including CE mark size requirements as per EC Regulation 765/2008, to assess the completeness and accuracy of regulatory content that software cannot evaluate contextually.

- All MDR Annex I §23.2 mandatory elements verified: manufacturer details, CE mark, UDI, device ID, dates, symbols, language, warnings, storage conditions
- CE mark: correct proportions per EC Regulation 765/2008, minimum 5mm height, NB identification number immediately adjacent, form not modified
- ISO 15223-1:2021 symbol verification: every symbol on the label traced to the ISO source; Symbol justification table produced
- Language completeness check against the EC MDR Language Requirements Table
- FDA 21 CFR Part 801 mandatory elements verified for US-market labels
- IVDR Annex I §20 compliance check for IVD device labels



 

#### Barcode &amp; UDI Verification

GS1 barcode verification and GS1 DataMatrix verification include comprehensive verification of all barcode elements, including symbology selection, data content, AI structure, quiet zones, X-dimension, and ISO/IEC print quality grade. Full UDI barcode verification decodes and checks the UDI carrier (DI + all PI elements) against the approved AI mapping record as part of UDI compliance services and UDI label verification.

- UDI-DI and all UDI-PI elements decoded from the AIDC carrier and verified against the approved GS1 AI mapping record or HIBC data structure
- GS1 Application Identifier (AI) structure verified: correct AI codes, correct data field format
- Barcode symbology confirmed: GS1 DataMatrix, GS1-128, or HIBC as appropriate
- Quiet zones verified per GS1 General Specifications v24: horizontal and vertical quiet zones measured
- X-dimension verified against the specification for the target print process and label size
- ISO/IEC 15415 (DataMatrix) or 15416 (GS1-128) grade assessment: target grade A (≥3.5); minimum grade C (≥2.5)
- HRI (Human-Readable Interpretation) verified for correct format, correct AI prefix display, and legible font size adjacent to AIDC symbol



 

#### Graphic &amp; Design Accuracy Check

Artwork inspection services include visual inspection and automated pixel-level comparison of all graphic elements against the approved design brief, brand guidelines, and master proof, covering medical device packaging compliance requirements. Electronic proofreading tool, Graphics Inspection, applied for automated image-level deviation detection.

- Logo and brand element accuracy verified against approved source files: version, color, proportions, clear space
- Color value verification: Pantone spot colors and CMYK builds confirmed against specification; no color substitutions or profile conversions
- Symbol sizing: ISO 15223-1:2021 minimum recommended dimensions verified for all symbols
- Layout element positions: all text zones, barcodes, logos, and symbols compared against approved design proof
- Dieline integration verified: label elements correctly positioned within bleed and safe zones



 

#### Pre-Press &amp; File Integrity Check

Technical validation of the production-ready artwork file, ensuring it is correctly prepared for print production and ready for medical device label approval. Preflight checks are applied to every PDF/X-4 file before approval release.

- Bleed, trim, and safe zone dimensions verified against the artwork specification and printer requirements
- All fonts embedded in the output PDF, no missing or substituted fonts that would cause rendering failures at the RIP stage
- Images at minimum 300 DPI (600 DPI recommended for fine text): no low-resolution image substitution
- Color mode correct: Pantone spot color channels present, CMYK builds correctly, no unintentional RGB objects
- Overprint settings verified: no text or barcode elements set to overprint incorrectly, causing drop-out on colored backgrounds
- PDF/X-4 compliance confirmed via preflight
- File version and naming confirmed: correct version number in filename and document metadata





- ![]()Comparative Text Verification
- ![]()Regulatory Compliance Review
- ![]()Barcode &amp; UDI Verification
- ![]()Graphic &amp; Design Accuracy Check
- ![]()Pre-Press &amp; File Integrity Check









## Freyr’s QC Framework: Error Detection and Prevention

These are the most common and consequential error types detected through medical device label artwork proofreading services and label compliance check reviews. These are among the most frequently identified and highest-risk error categories encountered during medical device artwork proofreading and reviews. If left undetected, they can lead to product recalls, production delays, market withdrawals, and patient safety risks.

| **Error Type** | **Description** | **Regulatory / Quality Impact** |
|---|---|---|
| **Text Transpositions** | Characters, numbers, or words in the wrong order, e.g., '10mg' vs '01mg', incorrect lot number sequence | May result in incorrect device identification, labeling inaccuracies, traceability issues, or product misbranding |
| **Missing Mandatory Elements** | Required MDR §23.2 or FDA 801 element absent, e.g., missing UDI, CE mark, NB number (where applicable), storage condition, or manufacturer's address | Potential non-conformity with MDR Annex I, Chapter III labeling requirements, and FDA labeling controls. |
| **Wrong Language Version** | Incorrect language applied to a market variant, or the required official EU language is absent | MDR Article 10(11) non-compliance; potentially restricting market access or triggering corrective actions. |
| **Incorrect / Outdated Symbols** | Use of obsolete, non-standard, unapproved, or incorrectly applied symbols; missing symbol explanations where required. | Potential non-conformance with MDR Annex I labeling requirements and ISO 15223-1 symbol standards. |
| **Barcode Content Error** | Incorrect GTIN, UDI-DI, Production Identifier (PI), Application Identifier (AI) structure, or data encoding within the barcode. | Potential non-compliance with UDI requirements under MDR Article 27 and FDA UDI regulations (21 CFR Part 830). |
| **Barcode Grade Failure** | Barcode passes visual check, but ISO/IEC 15415 grade is below the minimum threshold | Increased risk of barcode scanning failures, reduced traceability, supply chain disruption, and challenges in post-market surveillance activities. |
| **Date Format Error** | Incorrect, ambiguous, inconsistent, or non-approved date formats; missing expiration or manufacturing dates where required. | Potential labeling non-conformance, traceability issues, or regulatory observations. |
| **CE Mark Dimension Error** | CE mark below 5mm height, incorrect proportions, NB number not immediately adjacent | Potential non-conformance with MDR and CE marking requirements |
| **Color / Brand Error** | Incorrect color specifications, branding elements, warning colors, product family differentiation, or market-specific design requirements. | Brand inconsistency, packaging rejection, user confusion, or reduced effectiveness of risk communication elements. |
| **Pre-Press File Error** | Missing bleed, unembedded fonts, low-resolution images, incorrect color profile | Production delays, print-quality failures, artwork rework, increased manufacturing costs, and impacts on the launch timeline. |









## Freyr's Artwork QC Process







A structured, documented six-step label quality control services workflow from brief intake through multi-layer verification, findings reporting, re-review, and final release with a complete, signed QC record suitable for medical device label audit services produced for every artwork file.



![Booklet Labels &amp; Folded Inserts]()  

### QC Brief &amp; Document Intake

QC scope and review criteria are established based on device classification, intended use, target markets, language requirements, applicable regulations, and customer-specific quality standards.





![Booklet Labels &amp; Folded Inserts]()  

### Automated Inspection - Electronic Proofreading Tool

Text Inspection: Automated linguistic verification supported by approved software tools. Automated character-level comparison performed to identify discrepancies between approved source content and artwork output. Graphics Inspection: pixel-level comparison of the artwork against the approved master proof (where available). Barcode Inspection: automated decode and content verification of all barcodes. All automated findings flagged, categorized, and compiled.





![Booklet Labels &amp; Folded Inserts]()  

### Regulatory Compliance Review

Human regulatory specialist review of all mandatory content elements against the applicable standard; Symbols verified against the approved symbol library and applicable ISO 15223-1 requirements. CE marking presentation and associated Notified Body identification (where applicable) verified. Applicable national language requirements for each target market are verified. UDI carrier (AIDC + HRI) verified against the approved AI mapping record. Date formats verified for compliance with approved labeling specifications, applicable standards, and market requirements. In addition, check the requirements for authorized representative information, importer information (EU), sterility claims, single-use/reuse statements, MR safety symbols, eIFU references, safety warnings and contraindications, and storage conditions.





![Booklet Labels &amp; Folded Inserts]()  

### Barcode Grade &amp; Pre-Press Technical Verification

Barcode design parameters assessed against applicable GS1 and ISO requirements. Final barcode verification and grading should be performed on printed samples using calibrated verification equipment. Preflight on all production PDF files: fonts, image resolution (≥300 DPI), color mode, overprint settings, bleed and trim, and verification against customer-approved print production specifications (e.g., PDF/X standards where applicable).





![Booklet Labels &amp; Folded Inserts]()  

### QC Findings Report Compilation

All findings from automated and manual review are compiled into a structured QC findings report, categorized by severity: Major (blocks approval), Minor (must resolve before print release), Observation (advisory improvement). Each finding is documented with reference number, location, description, applicable regulatory reference, severity, and required corrective action. The artwork file is returned to the author for correction; it cannot proceed to the approval record stage until all major and minor findings are resolved and confirmed by the QC reviewer.





![Booklet Labels &amp; Folded Inserts]()  

### Re-Review, Approval &amp; Record Release

Corrected artwork re-submitted against all open QC findings. Targeted re-review of corrected elements plus a confirmation check that corrections have not introduced new errors elsewhere. Signed QC Completion Record issued documenting completion of the independent artwork quality review: QC reviewer full name, qualification/role, review date, artwork version number, and QC framework reference. Complete QC documentation package archived within the applicable Quality Management System. It is made available for inclusion within device history records, technical documentation, design history files, or equivalent quality records, as applicable.









## Regulatory Requirements for Artwork QC

Independent artwork proofreading and quality control are widely adopted industry practices used to demonstrate compliance with FDA, EU MDR, and ISO 13485 requirements for labeling accuracy, document control, and release verification. While the FDA, EU MDR, and ISO 13485 do not explicitly prescribe artwork proofreading methodologies, they require manufacturers to establish controls that ensure labeling accuracy, traceability, document control, and release verification. Independent artwork quality control is a widely adopted industry practice used to demonstrate compliance with these requirements and reduce the risk of labeling-related nonconformities, recalls, and patient safety events.





U.S. FDA

#### 21 CFR 820.120 - Device Labeling Controls



*The FDA's Quality System Regulation defines the specific labeling control requirements that manufacturers must maintain. 820.120 is frequently cited in FDA 483 observations and Warning Letters.*

- 820.120(a): Labeling integrity- labeling must be legible, securely affixed, and stored under appropriate conditions to prevent deterioration and contamination
- 820.120(b): Label inspection- each device's labeling must be inspected for accuracy, including expiration date, control number, and device identification, before release
- 820.120(c): Storage- labeling must be stored to prevent mix-ups and use of obsolete or incorrect labeling
- 820.120(d): Label issuance- procedures must ensure only correct labeling is used; documentation of issuance in the Device History Record
- 820.120(e): Traceability controls require accurate representation of device identifiers and control numbers where applicable.
- 21 CFR 820.30: Approved labeling specifications and associated review records are maintained within the applicable design and document control systems.







#### EU MDR

ISO 13485:2016



*EU MDR Article 10(9) requires a QMS that includes document control and labeling approval procedures. ISO 13485:2016 defines the production controls framework within which labeling QC operates.*

- ISO 13485 §7.5.1: Production and service provision controls require verification of activities to ensure labeling conforms to approved specifications.
- ISO 13485 §4.2.4: Document control- labeling specifications and approval records are controlled documents requiring version management
- MDR Article 10(9)(d): QMS must include documented procedures for labeling and packaging of devices
- MDR Annex II §2: Technical Documentation must include labeling demonstrating conformity with applicable Annex I requirements.
- MDR Article 10(3): Manufacturers are responsible for ensuring devices placed on the market comply with applicable MDR labeling requirements.
- ISO 13485 §8.3: Significant labeling discrepancies may require investigation and management through nonconformance and corrective action processes.







#### Technical Standards Governing QC Activities



*QC activities refer to a constellation of technical standards. Freyr applies all of these as a baseline in every artwork QC engagement.*

- ISO/IEC 15415:2011: Used as the reference standard for verification of printed 2D barcode quality.
- ISO/IEC 15416:2016: Used as the reference standard for GS1-128 and other linear symbols (grade A–F)
- ISO 15223-1:2021: Medical device symbols standard: source for all symbol accuracy verification
- GS1 General Specifications v24: Barcode structure, AI content, quiet zones, X-dimension requirements
- ISO 15930-7 (PDF/X-4): Print-ready PDF files may be verified against PDF/X standards required by the manufacturer's print production specifications.
- EC Regulation 765/2008: CE marking proportions and visibility requirements, including minimum size requirements where applicable.
- Applicable national language requirements of EU Member States.















## Freyr's Artwork QC Expertise

Delivered by specialists who understand both the design and compliance dimensions of medical device label artwork. Not just proofreading; a complete quality assurance framework.





01

🔍

### Truly Independent QC



One of the most common and significant weaknesses in artwork quality control (QC) is assigning the review to the individual responsible for creating the artwork. This compromises objectivity, increases the risk of undetected errors, and undermines the effectiveness of the QC process. Freyr addresses this challenge through a structurally independent QC framework, where specialized medical device artwork reviewers are not involved in artwork creation. This independence is embedded within Freyr’s service delivery model, ensuring that QC integrity is maintained even under tight timelines.

02

🤖

### Automated Inspection Tools as Standard



Electronic proofreading tools (automated proofreading software) are not an optional add-on but a core part of our artwork verification services in every Freyr QC engagement. Automated inspection eliminates human error and fatigue, provides pixel- and character-level accuracy, and generates objective, reproducible inspection reports that satisfy FDA DHR and Notified Body documentation expectations that manual review alone cannot meet.

03

⚖️

### Regulatory Specialists as Proofreaders



Freyr’s proofreading specialists are regulatory affairs professionals, not general-purpose proofreaders. They understand the significance of a missing NB number, an outdated ISO 15223-1 symbol, or an absent language version as part of a comprehensive medical device label compliance review and know how to document findings in a format that a Notified Body auditor or FDA investigator will recognize as adequate evidence of QC.

04

🔄

### Standalone or Integrated QC Models



Freyr’s medical device artwork experts provide quality control (QC) services either as a standalone medical device packaging artwork review engagement for artwork developed by external agencies or in-house teams, or as an integrated component of Freyr’s medical device label artwork services. For artwork developed by Freyr, QC is performed by a separate, independent reviewer within the same QMS. For externally developed artwork, Freyr provides independent third-party QC that most manufacturers cannot perform themselves.











## Frequently Asked Questions



### 01. Can the person who created the artwork also perform the QC review?

While FDA, MDR, and ISO 13485 do not explicitly require artwork review to be performed by a different individual, the industry’s best practice is to maintain independent verification wherever possible. Independent reviewers are more likely to identify errors that the original author may overlook due to familiarity with the content. Many manufacturers incorporate independent artwork reviews within their QMS as part of their labeling control procedures. Freyr's independent QC services provide an additional layer of objectivity and risk reduction before artwork approval and release.





### 02. What is the difference between automated inspection and manual proofreading?

Automated inspection tools (Electronic Proofreading Tool, TVT) use OCR and image-comparison algorithms to compare artwork against source documents at the character and pixel levels, eliminating human fatigue and detecting systematic deviations with high consistency. Automated tools can identify dimensional discrepancies and artwork deviations, but they cannot independently determine the regulatory appropriateness of labeling content, market-specific requirements, symbol usage, or intended context. Manual review by a regulatory specialist is essential for these context-sensitive checks. Freyr applies to both in every QC engagement because neither alone provides complete error coverage.





### 03. What documentation does Freyr provide as part of the QC record?

Every Freyr QC engagement produces: (1) QC Findings Report with all findings categorized by severity; (2) Electronic Proofreading Tool automated inspection reports (Text, Graphics, Barcode, Spelling); (3) TVT text comparison report; (4) Enfocus PitStop Pro preflight report; (5) Barcode grade assessment report; (6) Regulatory Compliance Checklist (MDR Annex I Chapter III (Sections 23.1–23.4) and applicable FDA labeling requirements); (7) Symbol Verification Table (ISO 15223-1:2021 cross-reference); (8) QC Completion Record or QC Review Record. This complete package is structured for documentation suitable for inclusion within device history records, technical documentation, or other quality records, as applicable.





### 04. How long does a Freyr artwork QC review take?

For a standard primary or secondary label artwork (single language, single format), Freyr typically completes the full 5-layer QC review within 24–48 business hours of receiving a complete QC brief with all source documents. For a multilingual artwork family (10+ language versions of a folding carton), the timeline is typically 3–5 business days. Expedited 24-hour QC service is available for urgent release situations. Turnaround time may vary based on artwork complexity, number of languages, and scope of review.





### 05. Can Freyr perform QC on artwork created by another agency or in-house?

Yes. This is one of the most common use cases for Freyr’s label artwork review services. Many manufacturers rely on these medical device labeling solutions to obtain independent QC of artwork produced by their in-house team or a third-party design agency. Freyr requires the source-approved label text, brand specification, applicable regulatory framework, and approved labeling specifications and applicable UDI information, where relevant, but no involvement in how the artwork was created. This separation enhances the independence of the QC review. Freyr's standalone QC service is available as an independent engagement, regardless of who created the artwork.





### 06. How are QC findings categorized and how does the resolution process work?

Every finding identified during QC is documented in the QC Findings Report with a reference number, the artwork location (page, zone, element), description of the discrepancy, applicable regulatory reference, severity classification (Major- blocks approval; Minor- must resolve before print; Observation-advisory), and required corrective action. The artwork cannot proceed to the approval record stage until all Major and Minor findings are confirmed and resolved by re-review. The complete findings and resolution history are archived as part of the QC Record, providing a traceable, defensible audit trail for each artwork version across its entire lifecycle.





### 07. Does artwork QC include UDI verification?

Yes. Freyr’s UDI barcode verification and UDI label verification services confirm the accuracy and consistency of UDI content, including Human Readable Interpretation (HRI), barcode data structure, Application Identifiers (AIs), and alignment with approved labeling specifications where applicable.





### 08. Does artwork QC include MDR symbol verification?

Yes. Regulatory symbols are verified against approved symbol libraries and applicable standards such as ISO 15223-1 to confirm correct usage and consistency across artwork components.





### 09. Can artwork QC support FDA inspections and Notified Body audits?

Yes. QC records provide documented evidence of labeling verification activities and may be used to support inspections, audits, and technical documentation reviews as part of the manufacturer's quality system.